EPever 4210an 40 Amp Charge Controller

An excellent charge controller for those with around 1 Kw in solar and are looking for a reliable unit they can expand upon.

Rated charging and discharging current: 40A. 12/24V DC automatically identifying system voltage. Max PV open circuit voltage: 100V; max PV input power: 520W/12V 1040W/24V. Common negative grounding.

$140.00

Out of stock

EPever 4210an 40 Amp Charge Controller

Description

The Tracer AN series is based on common negative design and advanced MPPT control algorithm, with LCD displaying running status.

Improving the MPPT control algorithm further, Tracer AN series can minimize the maximum power point loss rate and loss time, quickly track the maximum power point of the PV array and obtain the maximum energy from solar modules under any conditions; and can increase the ratio of energy utilization in the solar system by 10%-30% compared with a PWM charging method.

The limitation function of the charging power and current and reducing charging power function automatic improve the stability which works even connecting oversize PV modules and in high temperature, and increase the professional protection chip for the communication port, further improving the reliability and meeting the different application requirements.

With the adaptive three-stage charging mode based on a digital control circuit, Tracer AN series controllers can effectively prolong the life cycle of batteries, significantly improve the system performance and support all-around electronic protection functions, minimize damages to components of the system caused by incorrect installation or system failure at the utmost, and effectively ensure safer and more reliable operation of the solar power supply system for a longer service time.

Tracer 4210AN-1

Tracer 2210AN-3

  • While wiring the controller do not close the circuit breaker of fuse and make sure that the leads of “+” and “-” poles are connected correctly.
  • A fuse which current is 1.25 to 2 times the rated current of the controller, must be installed on the battery side with a distance from the battery not greater than 150 mm.
  • If the controller is to be used in an area with frequent lightning strikes or unattended area, it must be installed an external surge arrester.
  • If an inverter is to be connected to the system, connect the inverter directly to the battery, not to the load side of the controller.
  • Package List:
  • 1 x Solar Charge Controller
  • 1 x User Manual
Tennessee Valley Solar